NISSEI DSK-1031 Electronic Biceps (Forearm) Machine

ELECTRONIC FOREARM BLOOD PRESSURE MONITOR NISEY DSK1031

BASIC PRODUCT INFORMATION
The DSK1031 system is intended for non-invasive measurement of systolic and diastolic blood pressure and pulse determination of adults, incl. 12 years and up. This device is not intended for neonatal use. In addition, the results may be inaccurate if the device is measured on a child's hand. Consult your doctor if you want to measure a child's blood pressure. The product is recommended for use by patients with unstable blood pressure or with established hypertension at home as an adjunct to medical treatment. The sleeve accommodates an upper arm circumference of approximately 22 to 42 centimeters. The pressure is measured in the range of 0 to 300 mmHg, and the heart rate in the range of 40 to 160 beats/second.

INSTRUCTIONS FOR USE
This manual has been created to assist the user in the safe and efficient use of the DSK1031 Electronic Blood Pressure Monitor. The product must be used in accordance with the procedures described in this manual and must not be used for purposes other than those described herein. It is important to read and understand the entire manual. In particular, please read carefully and familiarize yourself with what is written in the "BLOOD PRESSURE MEASUREMENT TIPS" section.

WARRANTY OBLIGATIONS
1. The manufacturer guarantees conformity of the technical characteristics of the devices, provided that the user complies with the requirements for operation, transportation and storage during the warranty period - 5 years from the date of sale of the device. The warranty period for the sleeve and power supply is 12 months from the day of sale.
2. Warranty obligations are established with a warranty card upon sale of the device to the buyer. The warranty is valid on the condition that the device has not been opened and has not been damaged by the buyer.
3. The addresses of the companies providing warranty service are indicated in the warranty card.

The warranty does not apply if:
This warranty does not cover damage or malfunctions resulting from improper handling or use contrary to the instructions in this manual. There is a discrepancy in the warranty card; there is damage due to repairs by unauthorized persons or a service base: the damage occurred is a consequence of external factors: dust, liquids, exposure to unfavorable conditions; damage caused by impact or drop; improper operation and maintenance; natural wear and tear of parts.

SAFETY IN USE
Do not use the device without prior consultation with your attending physician in case you are undergoing dialysis treatment or are taking anticoagulants, antithrombotic drugs or steroids. Using the device under these conditions can lead to internal bleeding.
For specific information about your blood pressure, contact your doctor. Never draw independent conclusions regarding the measured results.
The material used to make the sleeve cover is rubber latex and may cause allergic reactions.
Do not use sleeves other than the one supplied with the product.
To avoid the possibility of accidental clamping, keep the instrument away from children and do not wrap the air tube around your neck.
Using the device near mobile phones, microwave ovens or other devices with a strong electromagnetic field may cause malfunction.
The system may refuse to report accurate results if it is used or stored at temperature and humidity outside the limits explained in the specification section of this manual.
Since the device contains elements for accurate measurement, measures should be taken to protect it from extreme fluctuations, humidity, shock, dust and direct sunlight. Don't drop it or hit it. Make sure the device is not exposed to moisture. The device is not waterproof.
Do not disassemble or modify the device.
Do not inflate the sleeve when it is not wrapped around your arm.

MEASUREMENT METHOD
This product applies the oscillometric principle to measure blood pressure and heart rate. The sleeve is connected to the body and wraps around the arm. Circles inside the sleeve detect the slight oscillations exerting pressure on the sleeve caused by the contraction and relaxation of the arteries in the arm in response to each heartbeat. The amplitude of each pressure wave is measured, converted to millimeters of mercury, and displayed on the LCD screen as an electronic unit. In the event that the pulse rhythm detected during the measurement is irregular, an indication of irregular pulse rhythm is visualized on the display. The last 30 results are stored in the memory along with date and time for comparison, and the average value of the stored information is calculated.

PRODUCT SPECIFICATION

Model: DSK1031;
Principle of operation: oscillometric method;
Indicator: 15 digital liquid crystal display;
Measurement during pumping;
Measurement of pulse pressure;
Arrhythmia indicator (irregular heart activity);
Pressure indication range: 3 to 300 mmHg (sleeve pressure);
Measuring range:
pressure in the sleeve, mm of mercury: 40-250;
pulse rate, beats per minute: 40-160;
Accuracy:
pressure in the cuff, mm: ±3;
pulse rate, % : ±5;
Pumping: automatic inflation;
Drop: automatic (via electronically controlled valve);
Exhaust: automatic exhaust valve;
Body motion sensor;
Power supply: Four LR6 batteries with a voltage of 1.5 V (alkaline battery AA) power supply unit;
Power consumption: 4 W (maximum);
Memory: 2 blocks, each 60 values + average value;
Operating environment: from +10 °C to + 40 °C, 15 - 85 % relative humidity;
Storage environment: from - 20 °C to + 60 °C, 10-95% relative humidity or lower;
Rigid cuff: arm circumference from 22 to 42 cm;
Main part: weight about 255 g (without batteries);
Dimensions: 115 x 115 x 65 mm (W x D x H);
Weight (without packaging, bag, batteries and power source): 406 g.

Important: Read the instructions for use.
The device complies with EMC (IEC 60601-1-2), EN1060-1 and EN1060-3.
Specifications are subject to change without notice due to performance improvements.

CARE, MAINTENANCE AND STORAGE
1. The device must be protected from high humidity, direct sunlight, vibration. THE DEVICE IS NOT WATERPROOF!
2. Do not store or use the device near heating devices and open fire.
3. If the device has been stored at a negative temperature, before using it, it must stand for at least 1 hour at room temperature.
4. If the device will not be used for an extended period of time, remove the batteries. Leaking batteries can damage it and void the warranty. KEEP BATTERIES OUT OF THE REACH OF CHILDREN!
5. Do not dirty the device and keep it away from dust. A soft cloth can be used to clean it.
6. The device as a whole and its parts should not come into direct contact with water, solvents, alcohol, gasoline.
7. Keep the cuff away from sharp objects and also do not try to pull it off.
8. Do not subject the device to strong impacts or throw it.
9. The device does not contain organs for adjusting the measurements. Independent opening of the electronic unit is prohibited. If necessary, carry out repairs only in specialized companies.
10. At the end of the operating period, the technical condition of the device must be periodically checked by specialized repair companies.
11. When disposing, you must comply with the rules in force in the given region. The manufacturer has not provided any special rules for recycling the device.

RECOMMENDATIONS FOR CORRECT MEASUREMENT OF BLOOD PRESSURE
1. When being treated with hemodialysis or anticoagulants, anti-platelets or steroids, consult your doctor in advance regarding blood pressure measurement.
2. When using the device near mobile phones, microwave ovens and other devices that generate electromagnetic radiation, there may be disturbances in operation.
3. In order to measure correctly, you must take into account that BLOOD PRESSURE IS SUBJECT TO SEVERE FLUCTUATIONS EVEN OVER SHORT PERIODS. The level of blood pressure is affected by many factors. It is usually lower in summer and higher in winter. Arterial pressure is affected by physical exertion, emotional excitability, stress and diet. Medicines, alcoholic beverages and smoking also have a big impact. In many people, even the very procedure of measuring blood pressure causes an increase in pressure values. Therefore, blood pressure measured at home often differs from that measured in the clinic. Because blood pressure increases at low temperatures, blood pressure measurements should be taken at room temperature (around 20°C). If the device has been stored at a low temperature, before using it, you must let it stand for at least 1 hour at room temperature, otherwise the measurement result may be inaccurate. Within a day, the difference in indicators for healthy people can be of the order of 30 - 50 mm of mercury column for the diastolic (lower limit) pressure. The dependence of arterial pressure on various factors is individual for each individual. Therefore, it is recommended to keep a special diary to record blood pressure values. ONLY THE DOCTOR CAN ANALYZE YOUR BLOOD PRESSURE TREND BASED ON THE DIARY DATA.
4. In the case of cardiovascular diseases and in some other diseases requiring monitoring of blood pressure, the measurements should be carried out at the times determined by the attending physician. REMEMBER THAT DIAGNOSIS AND ANY TREATMENT CAN ONLY BE PERFORMED BY A PHYSICIAN, BASED ON BLOOD PRESSURE VALUES OBTAINED BY LE(AR INDIVIDUALLY. TAKING OR CHANGING DOSAGE OF MEDICINES TAKEN SHOULD BE PERFORMED ONLY ON THE RECOMMENDATION OF THE TREATING PHYSICIAN.
5. In disorders of the type of deep vascular sclerosis, a weak pulse wave, and also in patients with strongly expressed disturbances of the rhythm of heart contractions, the correct measurement of arterial pressure can be difficult. IN SUCH CASES, IT IS NECESSARY TO CONSULT YOUR DOCTOR FOR THE CORRECT USE OF THE DEVICE.
TO GET CORRECT BLOOD PRESSURE READINGS WHEN USING THE ELECTRONIC DEVICE YOU MUST KEEP COMPLETE SILENCE DURING THE MEASUREMENT. Blood pressure measurement should be done in a quiet, comfortable environment at room temperature. You must not have eaten at least one hour before the measurement, and for an hour and a half - 2 hours before the measurement, you must not have smoked, consumed tonic drinks, or alcohol.
The accuracy of the blood pressure measurement also depends on how well the cuff size of the device corresponds to the size of your hand. THE SLEEVE SHOULD NOT BE TOO SMALL OR TOO LARGE FOR YOUR HAND.
Repeat measurements are made at 5-minute intervals to restore blood circulation. However, for those suffering from severe atherosclerosis due to significant loss of vessel elasticity, the time interval between measurements should be longer (10 - 15 minutes). The same applies to long-term diabetic patients. For a more accurate measurement of blood pressure values, a series of 3 consecutive measurements is recommended, and the average value of the results is considered as the result.

Causes of change in blood pressure:

Body movement;
Emotions;
Smoking;
Temperature, noise, etc.;
Conversation;
Nutrition;
Recent urination or bowel movements;
Change in environment, eg movement;
Mental stress;
Alcohol consumption.

Blood pressure measured at home is usually lower than blood pressure measured in a hospital, clinic, or doctor's office. This is due to the fact that you are tense in the hospital and calm at home. It is important to be informed about your stable usual blood pressure at home.
Have a qualified doctor interpret your blood pressure readings.
Depending on your age, weight and general condition, blood pressure may vary slightly. Consult your doctor to determine the blood pressure level that is normal for you.
Before taking a blood pressure reading, rest for about 5 minutes and take your blood pressure while resting in a quiet environment.
Measure blood pressure by standing in a suitable position and do not talk during the reading.
Avoid exercising, consuming food and alcohol, smoking, and other activities that may affect your blood pressure immediately before the measurement.
Take your blood pressure at the same time every day.
The ambient temperature when measuring blood pressure should be around 20 °C.

Classification of blood pressure (World Health Organization, 1999):

Hypertension Grade 1;
Hypertension Grade 2;
Hypertension Grade 3;
normal borderline;
normally optimal.

CORRECT MEASUREMENT POSITION
Sit on the table and place your arm on it while taking your blood pressure. Make sure to take the measurement in a place on the upper arm that is at about the same height as the heart, and the lower arm is stretched out and placed naturally on the table and remains still. You can lie on your back and take the measurement. Look at the ceiling, remain calm and do not move your neck or any other part of your body during the measurement. Again, make sure the measuring point is at about the same height as the heart.
The measured readings may vary slightly depending on the position during the measurement. If the sleeve is lower (higher) than the heart, the measured readings may be increased (lowered).

SLEEVE PLACEMENT
1. Place the sleeve on your left arm by positioning the air hose against your arm.
2. Wrap the sleeve around your arm with the end of the sleeve placed about 2-3 cm above the elbow. The air tube should be located on the palm side of the hand.
3. Press the surface of the sleeve to make sure it is securely fastened.
When wrapping the sleeve, wrap it loosely enough around the arm so that two fingers can be placed between the arm and the sleeve. In case the sleeve is wrapped too tightly or loosely, inaccurate results may be reported.
If you are wearing a shirt that can restrict blood circulation to the upper arm or have your sleeve rolled up over the upper arm, you will restrict blood flow and prevent an accurate blood pressure reading.

MEASUREMENT PROCEDURES
Insert the tube plug into the air connector.
Press the power button. A flashing air release signal is displayed.
The sleeve automatically inflates until the applied pressure is reached.
The pressure (the value shown on the display) begins to decrease, and the heart rate is indicated by a heart-shaped sign.
When the measurement is finished, the air is automatically released from the sleeve. Blood pressure and pulse are visualized on the display. The heart-shaped symbol flashes when the heart rate measured during the reading was at an abnormal level.
Press one of the two memory buttons 1 or 2 and the result will be stored in the memory function.
The display shows the number of the selected memory function. The result is saved in the selected memory when the unit is turned off. The measured abnormal heart rate is not saved, only the blood pressure and heart rate readings are saved. In case the measurement ended with an error, the result will not be saved.
Press the power button to turn off the device.
If you forget to turn off the device, it will automatically turn off after 3 minutes.
Take a deep breath and relax.
Do not move, talk or strain your arm during the measurement.

Termination of measurement
Press the on/off button and the inflation stops, the air is released to the outside and the monitor turns off.

Automatic re-inflation
In the event that the applied pressure is judged insufficient in the first phase of the measurement or arm or wrist movement is detected during the measurement, the device will re-inflate to a pressure approximately 40 mmHg higher. Inflation is repeated until the measurement is taken. However, this is not an indication of a problem. To control re-inflation manually, hold down the on/off button immediately after the start of inflation and release it when the pressure reaches a level 50 mmHg higher than the expected maximum systolic pressure If the pressure value has exceeded 180 mmHg, the inflation process will be terminated when the button is released. The pressure can be raised to about 300 mmHg.

Indication of abnormal heart rhythm
A flashing heart appears on the measurement result display, indicating an abnormal heart rhythm.
The abnormal heart rhythm may be the result of body movement during the measurement or an arrhythmia. Although the prolonged appearance of this symbol during a calm measurement can be a signal of arrhythmia, do not draw your own conclusions before consulting a doctor.
Do not take consecutive measurements because blood pooling can lead to false readings. Let your hand rest for at least 5 minutes.

THE SET CONTAINS:
- Electronic block - 1 pc.
- Sleeve (including air hose and air hose plug) - 1 pc.
- Batteries - 4 pcs.
- Power supply unit (adapter) - 1 pc.
- Bag - 1 pc.
- Operating instructions - 1 pc.
- Warranty card - 1 pc.
- Packaging - 1 pc.

Безплатна доставка за поръчки над 50 лв. без значение от теглото!

Цена от - доЦена на доставка
0 - 25 лв.3, 90 лв.
25 - 50 лв.3, 80 лв.
над 50 лв.Безплатна

* Доставката се осъществява в рамките на 3 работни дни до посочения адрес, след потвърждение на поръчката.
/ не важи по време на натоварени кампании - CYBER коледа, BIG WEEKEND SALE и други /.

При заявяване на поръчка до офис на Speedy, клиентът разполага със срок от 5 работни дни от датата на доставка, в които до приеме своята поръчка. След изтичането на срока, поръчката се анулира и се връща обратно на склад в subra.bg.

Add comment

0

More from same category